108 – Partitions.

§ 108. Partitions. All partitions shall rest directly upon the fireproof floor construction and never upon any wood flooring, and shall extend to the fireproof construction of the floor or roof above.

115 – Interior Water-Closets and Bathrooms.

§ 115. Interior water-closets and bathrooms. Interior water-closet compartments and bathrooms contained in fireproof multiple dwellings shall comply with the applicable provisions of section seventy-six.

117 – Employees’ Water-Closets.

§ 117. Employees’ water-closets. Water-closet compartments provided for domestic servants of tenants in multiple dwellings shall comply with the applicable provisions of section seventy-six.

107 – Public Halls.

§ 107. Public halls. 1. Every public vestibule or other public hall shall comply either with the provisions of section one hundred forty-nine for non-fireproof multiple dwellings, so far as applicable, or with the provisions of subdivision two of this section, except that the provisions as to ventilation shall not apply to any part of […]

102 – Stairs.

§ 102. Stairs. 1. Except as otherwise specifically provided in subdivisions three and four and in paragraphs b to j inclusive of subdivision six, every multiple dwelling which exceeds two stories in height shall have at least two fire-stairs. Such fire-stairs shall extend from the entrance story to the roof and be equipped with fireproof […]

103 – Egress From Apartments.

§ 103. Egress from apartments. 1. a. Except as provided in paragraph b of this subdivision, there shall be at least one means of egress from each apartment on each and every story of such apartment, and a second means of egress if the first means is not within fifty feet of every living room […]

104 – Bulkheads.

§ 104. Bulkheads. 1. Every stair, fire-stair and fire-tower required by this chapter to extend to the level of the roof or to any terrace formed by a setback shall extend to and through a fireproof bulkhead or other fireproof enclosure in such roof or terrace approved by the department. Such bulkhead or enclosure shall […]