244 – Spaces Under Stairs.

§ 244. Spaces under stairs. In non-fireproof tenements erected after April twelfth, nineteen hundred one, no closet of any kind shall be constructed or maintained under any stair leading from the entrance story to the upper stories, and such space shall be kept entirely open and clear of any encumbrance.

245 – Cellar Entrance.

§ 245. Cellar entrance. In tenements erected after April twelfth, nineteen hundred one, there shall be an entrance to the cellar, or to the basement or other lowest story if there be no cellar, from the outside of the tenement.

240 – First Tier of Beams.

§ 240. First tier of beams. 1. In all tenements erected after April twelfth, nineteen hundred one, which are five stories or more in height, the first floor above the lowest cellar, or, if there be no cellar, above the basement or other lowest story, shall be fireproof; and all exposed portions of any iron […]

241 – Partitions; Fire-Stopping.

§ 241. Partitions; fire-stopping. 1. In tenements erected after April eighteenth, nineteen hundred twelve, wood stud apartment partitions which are directly over each other shall run through the wood floor beams and rest upon the plate of the partition below. In fireproof tenements erected after such date all partitions shall rest directly upon the fireproof […]

242 – Cellar and Basement Stairs in Non-Fireproof Tenements.

§ 242. Cellar and basement stairs in non-fireproof tenements. 1. Cellar stairs in non-fireproof tenements erected after April twelfth, nineteen hundred one, which are occupied by three families or more on any story or which are five stories or more in height, shall be governed by the provisions of section one hundred fifty for non-fireproof […]

243 – Cellar and Basement Stairs in Fireproof Tenements.

§ 243. Cellar and basement stairs in fireproof tenements. In fireproof tenements erected after April eighteenth, nineteen hundred twelve, the cellar and basement stairs shall be located, arranged and constructed as provided in section one hundred six for fireproof dwellings erected after April eighteenth, nineteen hundred twenty-nine.

230 – Chimneys and Fireplaces.

§ 230. Chimneys and fireplaces. In every existing tenement which is not heated from a central heating plant there shall be adequate flues or chimneys through every floor with a fireplace or place for a stove properly connected with one of such flues or chimneys for every apartment.

231 – Egress.

§ 231. Egress. 1. Every non-fireproof tenement exceeding two stories in height and every fireproof tenement erected after May sixteenth, nineteen hundred thirteen, shall have at least two independent means of egress, which shall extend from the ground story to the roof, be located remote from each other and be separated from each other by […]

232 – Fire-Escapes.

§ 232. Fire-escapes. 1. All fire-escapes erected after April eighteenth, nineteen hundred twenty-nine, shall be arranged and constructed in conformity with the provisions of section fifty-three. 2. As specifically indicated in subdivision nine of section fifty-three, a wire, chain, cable, vertical ladder, or rope fire-escape is an unlawful means of egress from any apartment. Every […]

233 – Bulkheads and Scuttles.

§ 233. Bulkheads and scuttles. 1. Every tenement, except as in this section otherwise provided, shall have in the roof a fireproof bulkhead with a fireproof door and after January first, nineteen hundred fifty-seven, the door shall be self-closing. Bulkheads existing on April eighteenth, nineteen hundred twenty-nine, shall be lawful and may be replaced or […]