US Lawyer Database

Section 113 – Amendments to Chapters 32 through 35 of IBC.

Effective 7/1/2021 15A-3-113. Amendments to Chapters 32 through 35 of IBC. (1) In IBC, Chapter 35, the referenced standard for NFPA 70-17 is deleted and replaced with NFPA 70-20. (2) In IBC, Chapter 35, the referenced standard ICCA117.1-09, Section 606.2, Exception 1 is modified to include the following sentence at the end of the exception: […]

Section 201 – General provision.

Effective 5/13/2014 15A-3-201. General provision. (1) The amendments in this part are adopted as amendments to the IRC to be applicable statewide. (2) The statewide amendments to the following which may be applied to detached one- and two-family dwellings and multiple single-family dwellings shall be applicable to the corresponding provisions of the IRC: (a) IBC […]

Section 202 – Amendments to Chapters 1 through 5 of IRC.

Effective 7/1/2022 15A-3-202. Amendments to Chapters 1 through 5 of IRC. (1) In IRC, Section R102, a new Section R102.7.2 is added as follows: “R102.7.2 Physical change for bedroom window egress. A structure whose egress window in an existing bedroom is smaller than required by this code, and that complied with the construction code in […]

Section 203 – Amendments to Chapters 6 through 15 of IRC.

Effective 7/1/2022 15A-3-203. Amendments to Chapters 6 through 15 of IRC. (1) In IRC, Section N1101.5 (R103.2), all words after the words “herein governed.” are deleted and replaced with the following: “Construction documents include all documentation required to be submitted in order to issue a building permit.” (2) In IRC, Section N1101.12 (R303.3), all wording […]

Section 204 – Amendments to Chapters 16 through 25 of IRC.

Effective 5/5/2021 15A-3-204. Amendments to Chapters 16 through 25 of IRC. (1) In IRC, Section M1602.2, a new exception is added at the end of Item 6 as follows: “Exception: The discharge of return air from an accessory dwelling unit into another dwelling unit, or into an accessory dwelling unit from another dwelling unit, is […]

Section 205 – Amendments to Chapters 26 through 35 of IRC.

Effective 7/1/2022 15A-3-205. Amendments to Chapters 26 through 35 of IRC. (1) A new IRC, Section P2602.3, is added as follows: “P2602.3 Individual water supply. Where a potable public water supply is not available, individual sources of potable water supply shall be utilized, provided that the source has been developed in accordance with Utah Code, […]

Section 206 – Amendments to Chapters 37, 39, and 44 and Appendix F of IRC.

Effective 7/1/2022 15A-3-206. Amendments to Chapters 37, 39, and 44 and Appendix F of IRC. (1) In IRC, Section E3601.6.2, a new exception is added as follows: “Exception: An occupant of an accessory dwelling unit is not required to have access to the disconnect serving the dwelling unit in which they reside.” (2) In IRC, […]

Section 301 – General provision.

15A-3-301. General provision. The amendments in this part are adopted as amendments to the IPC to be applicable statewide. Enacted by Chapter 14, 2011 General Session

Section 302 – Amendments to Chapters 1 and 2 of IPC.

Effective 7/1/2019 15A-3-302. Amendments to Chapters 1 and 2 of IPC. (1) In IPC, Section 202, the definition for “Backflow Backpressure, Low Head” is deleted. (2) In IPC, Section 202, the following definition is added: “Certified Backflow Preventer Assembly Tester. A person who has shown competence to test Backflow prevention assemblies to the satisfaction of […]

Section 303 – Amendments to Chapter 3 of IPC.

Effective 7/1/2019 15A-3-303. Amendments to Chapter 3 of IPC. (1) In IPC, Section 303.4, the following exception is added:“Exception: Third-party certification for backflow prevention assemblies will consist of any combination of two certifications, laboratory or field. Acceptable third party laboratory certifying agencies are ASSE, IAPMO, and USC-FCCCHR. USC-FCCCHR currently provides the only field testing of […]