51010. It is the intent of the Legislature, in enacting this chapter, that the State Fire Marshal shall exercise exclusive safety regulatory and enforcement authority over intrastate hazardous liquid pipelines and, to the extent authorized by agreement between the State Fire Marshal and the United States Secretary of Transportation, and may act as agent for […]
51010.5. As used in this chapter, the following definitions apply: (a) “Pipeline” includes every intrastate pipeline used for the transportation of hazardous liquid substances or highly volatile liquid substances, including a common carrier pipeline, and all piping containing those substances located within a refined products bulk loading facility that is owned by a common carrier and […]
51010.6. Notwithstanding Section 51010.5, that portion of an interstate pipeline that is located within this state and is subject to an agreement between the United States Secretary of Transportation and the State Fire Marshal is subject to the federal Hazardous Liquid Pipeline Safety Act of 1979 (49 U.S.C. Sec. 60101 et seq.). (Amended by Stats. […]
51011. (a) The State Fire Marshal shall adopt hazardous liquid pipeline safety regulations in compliance with the federal law relating to hazardous liquid pipeline safety, including, but not limited to, compliance orders, penalties, and inspection and maintenance provisions, and including amendments to those laws and regulations that may be hereafter enacted and adopted. Regulations adopting the […]
51012. The State Fire Marshal shall establish a Pipeline Safety Advisory Committee for purposes of informing local agencies and every pipeline operator of changes in applicable laws and regulations affecting the operations of pipelines and reviewing proposed hazardous liquid pipeline safety regulations adopted pursuant to Section 51011. The committee shall be composed of eight members […]
51012.4. (a) Notwithstanding any other provision of this chapter, including, but not limited to, Section 51012.3, each pipeline operator shall file with the State Fire Marshal, on or before July 1, 2000, an inspection, maintenance, improvement, or replacement assessment for the following: (1) Any pipeline or pipeline segments built before January 1, 1960. (2) Any pipeline installed on […]
51013. (a) Any new pipeline constructed after January 1, 1984, and which normally operates under conditions of constant flow and pressure, shall be designed and constructed in accordance with Subparts C and D of Part 195 of Title 49 of the Code of Federal Regulations, and shall include a means of leak detection and cathodic protection […]
51013.1. (a) By January 1, 2018, any new or replacement pipeline near environmentally and ecologically sensitive areas in the coastal zone shall use best available technology, including, but not limited to, the installation of leak detection technology, automatic shutoff systems, or remote controlled sectionalized block valves, or any combination of these technologies, based on a risk […]
51013.5. (a) Every newly constructed pipeline, existing pipeline, or part of a pipeline system that has been relocated or replaced, and every pipeline that transports a hazardous liquid substance or highly volatile liquid substance, shall be tested in accordance with Subpart E (commencing with Section 195.300) of Part 195 of Title 49 of the Code of […]
51014. (a) The pressure tests required by subdivisions (b), (c), and (d) of Section 51013.5 shall be conducted in accordance with Subpart E (commencing with Section 195.300) of Part 195 of Title 49 of the Code of Federal Regulations, except that an additional four-hour leak test, as specified in Section 195.302(c) of Title 49 of the […]
51014.3. (a) Each pipeline operator shall notify the State Fire Marshal and the local fire department having fire suppression responsibilities at least three working days prior to conducting a hydrostatic test which is required by this chapter. The notification shall include all of the following information: (1) The name, address, and telephone number of the pipeline operator. […]
51014.5. (a) When hydrostatic testing is required by Section 51013.5, the test results shall be certified by an independent testing firm or person who is selected from a list, provided by the State Fire Marshal, of independent testing firms or persons approved annually by the State Fire Marshal. The State Fire Marshal may charge a fee […]
51014.6. (a) Effective January 1, 1987, no person, other than the pipeline operator, shall do any of the following with respect to any pipeline easement: (1) Build, erect, or create a structure or improvement within the pipeline easement or permit the building, erection, or creation thereof. (2) Build, erect, or create a structure, fence, wall, or obstruction adjacent […]
51015. (a) A pipeline operator shall provide to the fire department having fire suppression responsibilities a map or suitable diagram showing the location of the pipeline, a description of all products transported within the pipeline, and a contingency plan for pipeline emergencies that shall include, but not be limited to, any reasonable information that the State […]
51015.05. (a) The State Fire Marshal shall establish and maintain a centralized database containing information and data regarding the following intrastate pipelines: (1) Pipelines used for the transportation of crude oil that operate by gravity or at a stress level of 20 percent or less of the specified minimum yield strength of the pipe. (2) Pipelines used for […]
51015.1. (a) Commencing January 1, 2017, the State Fire Marshal, or an officer or employee authorized by the State Fire Marshal, shall annually inspect all intrastate pipelines and operators of intrastate pipelines under the jurisdiction of the State Fire Marshal to ensure compliance with applicable laws and regulations. By January 1, 2017, the State Fire Marshal […]
51015.2. (a) The Legislature recognizes that hazardous liquid pipelines are often located alongside and in the immediate proximity of rail lines. In the event of a derailment, these pipelines may be damaged in such a fashion that their integrity is lost, making a rupture or leak more likely. (b) In an effort to better protect public safety, […]
51015.3. The State Fire Marshal may, in the interest of public safety, adopt emergency regulations which govern intrastate pipeline emergencies involving railroad car derailments. Any hazardous liquid pipeline located in a rural area shall be exempt from these regulations. Notwithstanding any other provision of law, these emergency regulations shall remain in effect until permanent regulations […]
51015.4. (a) Each operator shall, as specified in regulations provided for in subdivision (c), maintain each valve and check valve that is necessary for the safe operation of its pipeline systems in good working order at all times. (b) Each operator shall provide protection for each valve and check valve from unauthorized operation and from vandalism. (c) The […]
51015.5. (a) In the event of an intrastate pipeline rupture, leak, or other incident which could affect safe pipeline operation, any person who performs or intends to perform nonemergency site cleanup, repair, reconstruction, or any other alteration shall obtain prior approval from the State Fire Marshal. (b) Approval by the State Fire Marshal of a repair […]