Section 7965.

7965. Any tunnel or underground mine classified by the division as gassy shall operate under special procedures adopted by the board, as well as rules, regulations, special orders, or general orders for nongassy underground mines and tunnels. (Added by Stats. 1972, Ch. 1430.)

Section 7966.

7966. In any tunnel classified as gassy by the division, there shall be tests for gas or vapors taken prior to each shift and at least hourly during actual operation. If a mechanical excavator is used, gas tests shall be made prior to removal of muck or material and before any cutting or drilling in […]

Section 7967.

7967. Whenever gas levels in excess of 10 percent of the lower explosive limit are encountered initially in a tunnel or underground mine classified as gassy, the division shall be notified immediately by telephone or telegraph. The chief of the division or his authorized representative may waive subsequent notification for gas readings less than 20 […]

Section 7968.

7968. In any gassy tunnel or underground mine, the division may order work halted until adequate testing can be completed to determine the level of hazard from gases or vapors. A notice of such shutdown shall be filed by the division inspector with his superiors as soon as practicable. Any overruling of such order must […]

Section 7969.

7969. In any gassy tunnel or underground mine the division shall review plans for electrical lighting and power for equipment. When it is necessary for safety, the inspector may require changes in the amount and type of lighting, and may require permissive-type wiring, switches, tools, and equipment. (Added by Stats. 1972, Ch. 1430.)

Section 7970.

7970. In any tunnel or underground mine classified gassy, smoking shall be prohibited and the employer shall be responsible for collecting all personal sources of ignition such as lighters and matches from employees entering the tunnel. (Added by Stats. 1972, Ch. 1430.)

Section 7971.

7971. Whenever there is any ignition of gas or vapor in a tunnel or underground mine, all work shall cease, employees shall be removed, and reentry except for rescue purposes shall be prohibited until the division has conducted an inspection and authorized reentry for maintenance or production in writing. (Added by Stats. 1972, Ch. 1430.)

Section 7972.

7972. If the level of gas in any tunnel or underground mine reaches 20 percent of its lower explosive limit at any time all men shall be removed, the division notified immediately by telephone or telegram, and no one shall reenter the tunnel or underground mine until approval is given by the division. (Added by […]

Section 7973.

7973. In any tunnel or underground mine classified as gassy, all employees shall be informed of any special orders made by the division following an inspection. Such notice shall be given before entering the tunnel or underground mine. A copy of any orders subsequently written by the division shall be posted and all employees shall […]

Section 7974.

7974. In any tunnel classified as gassy by the division, ventilation shall include continuous exhausting of fumes and air, unless an alternative ventilation plan which is as effective or better is approved by the division. Fans for this purpose shall be located at the surface, and shall be reversible from a single switch at the […]

Section 7975.

7975. A “kill” button capable of cutting off all electrical equipment shall be maintained in any gassy tunnel or underground mine. The safety representative or his designated representative shall cut off power at any time gas or vapor levels reach 20 percent of the lower explosive limit or more. Before work is restarted every employee […]

Section 7976.

7976. In any tunnel or underground mine classified as gassy, the division shall determine the number of fire extinguishers necessary and their locations. (Added by Stats. 1972, Ch. 1430.)

Section 7977.

7977. Any tunnel or underground mine classified as extrahazardous by the division shall comply with the provisions for gassy tunnels in this chapter, as well as regulations, rules, special orders, and general orders of the division or board. (Added by Stats. 1972, Ch. 1430.)

Section 7978.

7978. In any extrahazardous tunnel or underground mine smoking by employees or open flame shall be prohibited. Welding or cutting with arc or flame underground in other than fresh air shall be done under the direct supervision of qualified persons who shall test for gas and vapors before welding or cutting starts and continuously during […]

Section 7979.

7979. In tunnels or underground mines classified extrahazardous, sufficient air shall be supplied to maintain an atmosphere of all of the following conditions: (a) Not less than 19 percent oxygen. (b) Not more than 0.5 percent carbon dioxide. (c) Not more than 5 parts per million nitrogen dioxide. (d) No petroleum vapors or other toxic gases in concentrations exceeding […]

Section 7980.

7980. All electrical equipment and machines, including diesel engines, used in tunnels or underground mines classified extrahazardous shall be permissible equipment. The division may, however, permit the use of nonpermissive equipment in a tunnel or underground mine in areas where it finds there is no longer danger from gas or other hazards. (Added by Stats. […]

Section 7981.

7981. An escape chamber or alternate escape route shall be maintained within 5,000 feet of the tunnel face or areas being used to excavate material in an underground mine classified as gassy or extrahazardous. Workers shall be provided with emergency rescue equipment and trained in its use. (Added by Stats. 1972, Ch. 1430.)

Section 7982.

7982. Records of air flow and air sample tests to assure compliance with required standards shall be maintained by the employer at the site of any tunnel or underground mine classified extrahazardous. Such records shall be made available to any division representative upon request. (Added by Stats. 1972, Ch. 1430.)

Section 7983.

7983. The main fan line used for ventilation in any tunnel or underground mine classified extrahazardous shall contain a cutoff switch capable of halting all machinery underground automatically should the fan fail or its performance fall below minimum power needed to maintain a safe atmosphere. (Added by Stats. 1972, Ch. 1430.)

Section 7984.

7984. In any tunnel or underground mine classified extrahazardous a device or devices which automatically and continuously test the atmosphere for gases or vapors shall be maintained. Such device or devices shall be placed as near the face or area of operation as practical, but never more than 50 feet from such point. The division […]