7983. The main fan line used for ventilation in any tunnel or underground mine classified extrahazardous shall contain a cutoff switch capable of halting all machinery underground automatically should the fan fail or its performance fall below minimum power needed to maintain a safe atmosphere. (Added by Stats. 1972, Ch. 1430.)

Section 7984.

7984. In any tunnel or underground mine classified extrahazardous a device or devices which automatically and continuously test the atmosphere for gases or vapors shall be maintained. Such device or devices shall be placed as near the face or area of operation as practical, but never more than 50 feet from such point. The division […]

Section 7985.

7985. All such testing device or devices shall be U.S. Bureau of Mines approved or acceptable to other authorities recognized by the division and shall automatically sound an alarm and activate flashing red signals visible to employees underground whenever the concentration of gases or vapors reaches or exceeds permissible levels. Permissible levels may be established […]

Section 7970.

7970. In any tunnel or underground mine classified gassy, smoking shall be prohibited and the employer shall be responsible for collecting all personal sources of ignition such as lighters and matches from employees entering the tunnel. (Added by Stats. 1972, Ch. 1430.)

Section 7971.

7971. Whenever there is any ignition of gas or vapor in a tunnel or underground mine, all work shall cease, employees shall be removed, and reentry except for rescue purposes shall be prohibited until the division has conducted an inspection and authorized reentry for maintenance or production in writing. (Added by Stats. 1972, Ch. 1430.)

Section 7972.

7972. If the level of gas in any tunnel or underground mine reaches 20 percent of its lower explosive limit at any time all men shall be removed, the division notified immediately by telephone or telegram, and no one shall reenter the tunnel or underground mine until approval is given by the division. (Added by […]

Section 7965.

7965. Any tunnel or underground mine classified by the division as gassy shall operate under special procedures adopted by the board, as well as rules, regulations, special orders, or general orders for nongassy underground mines and tunnels. (Added by Stats. 1972, Ch. 1430.)

Section 7966.

7966. In any tunnel classified as gassy by the division, there shall be tests for gas or vapors taken prior to each shift and at least hourly during actual operation. If a mechanical excavator is used, gas tests shall be made prior to removal of muck or material and before any cutting or drilling in […]

Section 7967.

7967. Whenever gas levels in excess of 10 percent of the lower explosive limit are encountered initially in a tunnel or underground mine classified as gassy, the division shall be notified immediately by telephone or telegraph. The chief of the division or his authorized representative may waive subsequent notification for gas readings less than 20 […]

Section 7968.

7968. In any gassy tunnel or underground mine, the division may order work halted until adequate testing can be completed to determine the level of hazard from gases or vapors. A notice of such shutdown shall be filed by the division inspector with his superiors as soon as practicable. Any overruling of such order must […]